17. Department press release on Expert panel recommends further tests on cladding and insulation - exhibit to MHCLG Building Safe CLG10003087.pdf [pdf]
… press release on Expert panel recommends further tests on cladding and insulation - exhibit to MHCLG Building Safe … press release on Expert panel recommends further tests on cladding and insulation - exhibit to MHCLG Building Safe … material panels, with core filler materials of unmodified polyethylene, fire retardant polyethylene, and …
Published on:
KIN00004658_Internal Kingspan email correspondence discussing upcoming testing program in Dubai & Uster University, the make up of the systems & products to be used & introducing as many weak.pdf [pdf]
… fibre insulation system (binder content / presence of polyethylene adhered aluminium foil). However, we do not … fibre insulation system (binder content / presence of polyethylene adhered aluminium foil). However, we do not … fibre insulation system (binder content / presence of polyethylene adhered aluminium foil). However, we do not …
Published on:
BRE00043755_Exhibit DC_99 – Fires of Special Interest Report concerning Bennett Close fire on 10 June 2008..pdf [pdf]
… through the majority of the building; between the exterior cladding system and the timber frame was a cavity much of … of mineral wool wrapped in plastic material (possibly polyethylene/polypropylene) (Figure 26). Attached to the … were a number of plastic airbdcks penetrating the exterior cladding of the walls at a number of locations throughout …
Published on:
KIN00000501_Appendix B to the Witness statement of Adrian Pargeter (Kingspan).pdf [pdf]
… AS AT SUPPLY DATE Date of test Test house Commissioned by Cladding Panel tested Insulation tested BS 8414 Report … K IN 00000501/1 Date of test Test house Commissioned by Cladding Panel tested Insulation tested BS 8414 Report … Government "ACM panel with a core filler of fire retardant polyethylene" "Insulation material of rigid phenolic foam"2 …
Published on:
KIN00020869_Appendix A to the second Witness Statement of Adrian Pargeter.docx - document undated..pdf [pdf]
… 8414 TEST REPORTS AS AT MAY 2015 Date Test house Commission Cladding Panel Insulation tested BS 8414 Report BR 135 …
Published on:
AASR0000024_Appendix XIV- Selection of Fire Conditions and Fire Effluent Analysis for Different Materials Tested in the Steady State Tube Furnace.pdf [pdf]
… a much smaller proportion of the overall external cladding, only two fire conditions were tested. For these 6 … because they were not part of the combustible external cladding system, and would therefore not have contributed to …
Published on:
HAR00010311_Exhibit RB_51 (0520 - Reynobond_ColourChart_Design_WoodDesign.pdf) - Ray Bailey (Harley).pdf [pdf]
Published on:
RYD00094257_Exhibit NMY279 - Rockwool datasheet for Firepro SP Firestop Systems, dated September 2012.pdf [pdf]
… cutting guide lines on the surface of each slab. External cladding Where used in conjunction with profiled metal cladding, cut the ROCKWOOL ® SP Firestop Slab to suit the … easy to handle. They are supplied in compression wrapped polyethylene, which will provide short term protection. For …
Published on:
BBA00010739_Exhibit JA_22 - Quality plans relating to certificate 08_4510.pdf [pdf]
… Agreed Quality plan for Reynobond Architecture Wall Cladding Panels Agrement Certificate 08/4510 Document … BBA00010739/1 Product name: Reynobond Architecture Wall Cladding Panels Product range: The Reynobond Architecture Wall Cladding Panels are aluminium composite panels consisting of …
Published on:
BBA00010737_Exhibit JA_20 - Quality plans relating to certificate 08_4510.pdf [pdf]
… Agreed Quality plan for Reynobond Architecture Wall Cladding Panels Agrement Certificate 08/4510 Document … BBA00010737/1 Product name: Reynobond Architecture Wall Cladding Panels Product range: The Reynobond Architecture Wall Cladding Panels are aluminium composite panels consisting of …
Published on:
BBA00009671 - Extract - BBA Certificate Contract for Reynobond aluminium_polythylene composite wall cladding panels, Reference No S3_41014, and other Reynobond correspondence and certification documents.pdf [pdf]
… Contract for Reynobond aluminium_polythylene composite wall cladding panels, Reference No S3_41014, and other Reynobond … Contract for Reynobond aluminium_polythylene composite wall cladding panels, Reference No S3_41014, and other Reynobond … ~ .-..) f8_S:, Nature of product or process: Aluminurn/polyethylene composite wall cladding~ Ill The Address(es) of …
Published on:
WIN00000005_Witness Statement of Christopher Macey dated 3 November 2021.pdf [pdf]
… 10. Wintech are sponsors of the Centre for Window and Cladding Technology (CWCT) and this provides an opportunity … understanding of the fire safety requirements for external cladding systems under the Building Regulations and … familiar with A CMpanels with a combustible core, such as polyethylene? Please set out what you knew about their …
Published on:
EXO00001849_Exova BR 135 Desktop Assessment Report - The External Fire Spread Performance of Façade Construction incorporating Celotex RS5000, for Grange Walk, Bermondsey in relation to the re.pdf [pdf]
… 100 mm or 215mm brickwork external skin Or- PPC aluminium Cladding panel cassette, Or - STO extemal thermal insulation … with Steeltherm roll) Vapour control layer (125 micron Polyethylene) 140 mineral wool (Earthwool A double layer of … Report No. 355647 Page 6 of 20 Proposals -2 Aluminium cladding General The Facade Construction evaluated in this …
Published on:
HOM00005818_Document entitled Warwickshire Fire and Rescue Service operational bulletin regarding research on cladding.pdf [pdf]
… Rescue Service operational bulletin regarding research on cladding.pdf HOM00005818_Document entitled Warwickshire Fire … Rescue Service operational bulletin regarding research on cladding.pdf OB 12/02 March 2012 WARWICKSHIRE FIRE AND … Fire Development Certain types of fuels, for example polyethylene, polypropylene or other similar plastics can …
Published on:
BBA00011007_ETA-06 0189 en.pdf [pdf]
… (EPS shuttering leaves) and ties of high density plastic (polyethylene) (HOPE ties). The shuttering elements are … within the HOPE tie design provide a fixing for dry lining, cladding and temporary propping or bracing. The maximum … are to be protected by finishes (e. g. rendering, plasters, cladding, panelling, coatings). Finishes are not part of the …
Published on:
BBA00010725_BBA Exhibit JA_6 - Contract between BBA and Alcoa Architectural Products.pdf [pdf]
… I' •· •• - ~!'-)~$, Nature of product or process: Aluminum/polyethylene composite wall cladding ~ Ill The Address(es) of the place(s) where the …
Published on: