MAX00000334_Curtins Consulting - Summary of Structural Concrete Investigation Works and Concrete Dust Sample Testing at Grenfell Tower by CAN London Ltd including unnamed, undated drawings.pdf [pdf]
… take four concrete dust samples from the precast concrete cladding panels that wraps around the external face of the … Take four concrete dust samples from the precast concrete cladding panels that wraps around the external face of the … Take four concrete dust samples from the precast concrete cladding panels that wraps around the external face of the …
Published on:
LABC0020133_Exhibit CB_16 - FDS Consult Fire Engineer's Report.pdf [pdf]
… Standard (BS) 8414: Par[ 2 Fire Performance of External Cladding Systems: 2005 and the Building Control Alliance … London. The series of tests included 7 combinations of cladding systems; 3 common types of Aluminium Composite … of BCA Technical Guidance Note 18 - Use of combustible cladding materials on residential buildings, for the use of …
Published on:
RYD00004085_Email from Mike Albiston to Simon Lawrence_1.pdf [pdf]
… Simon Lawrence Grenfell Tower, London - Nedzink Rainscreen Cladding Proteus HR Brochure_spreads.pdf; Nedzink_ Draft … following information from KME forthe Proteus Rainscreen cladding:- • Typical draft guarantees • New sales brochure • … Simon Lawrence Grenfell Tower, London - Nedzink Rainscreen Cladding Proteus HR Brochure_spreads.pdf; Nedzink_ Draft …
Published on:
CLG00019192_Emails between Sam Greenwood (ARUP) and Brian Martin discussing the initial reports of the police fire _investigation_ into the tower fire in Dubai_0.pdf [pdf]
… fire in Manchester that signalled the end of "rainscreen cladding". Currently inl and saw the initial reports of the … the fire quickly spread up the highly-flammable building cladding - which contained aluminium and flbreglass - to the … fire in Manchester that signalled the end of "rainscreen cladding". Currently inl and saw the initial reports of the …
Published on:
BRE00043690_Exhibit TL_2 - Final publishable guidance for Workstream 3 (BD2887)_ Compartment sizes, resistance to fire and fire safety project, Final publishable guidance for Workstream 3, BRE.pdf [pdf]
… excludes testing of cavity barriers in external cladding systems which should be considered when using a … not applicable to horizontal barriers in e.g. rain screen cladding because it is difficult if not impossible to model … a masonry wall usually used to assess the performance of cladding systems to BS 8414-1:20023°. In this case, two …
Published on:
GTI - Day 131.pdf [pdf]
Published on:
Witness statement - Dominic Fearnley MET00008020.pdf [pdf]
… falling from the building was large, it seemed to be mainly cladding panels that were falling, they were giving off … see this was going into the building, rather than onto the cladding. This was the Ariel platform from Surrey, the … was because of the supply of gas. I have no knowledge of cladding used on residential buildings, I am aware that …
Published on:
Witness statement - Terrence Lowe MET00007969.pdf [pdf]
… the tower because of the falling debris, lumps of burning cladding and hot cinders were all coming down around the … watching debris coming down and lots of pieces of burning cladding were falling. I'm not sure who but someone took … on the fire what so ever, the jet had no effect on the cladding. It was then that I saw the extent of the fire to …
Published on:
RYD00008958_Email from Simon Lawrence to Stephen Morris_0.pdf [pdf]
… in the region of £33,000 of ECO funding towards the thermal cladding and communal heating system replacement works, net … a Green Deal Home Improvement Fund (GDHIF) for the thermal cladding. This is dependent upon KCTMO going through all … Windows to each flat along with an insulated Rainscreen cladding system externally around the building. > New …
Published on:
RYD00005631_Email from Tom Vosper to Simon Lawrence_0.pdf [pdf]
… in the region of £33,000 of ECO funding towards the thermal cladding and communal heating system replacement works, net … a Green Deal Home Improvement Fund (GDHIF) for the thermal cladding. This is dependent upon KCTMO going through all … Windows to each flat along with an insulated Rainscreen cladding system externally around the building. > New …
Published on:
CEL00003218_Email from Paul Evans to Bex Hartlebury about the advert for RS5000, stating that it is the first PIR insulation suitable for use above 18m in height.pdf [pdf]
… celotex RSSOOO. Designed specifically as a rainscreen cladding solution, RSSOOO is the first PIR insulation … of 'these' but if not we will need to repeat 'rainscreen cladding' which isn't ideal in the same sentence/paragraph. … celotex RSSOOO. Designed specifically as a rainscreen cladding solution, RSSOOO is the first PIR insulation …
Published on:
BRE00012252_Email from Sarah Colwell to Debbie Smith & Stephen Howard re LABC Certificate for Kingspan K15, requesting urgent discussion (attaching Certificate).pdf [pdf]
… Stephen Cc= MacDonald, Norman; Smith, Debbie Subject= Cladding test - LABC assessments Hi Folks I have managed to … a rain cavity gap of 50ram with a range of rainscreen claddings. I am sure that this will be sent to us officially … Stephen Cc= MacDonald, Norman; Smith, Debbie Subject= Cladding test - LABC assessments Hi Folks I have managed to …
Published on:
INQ00014936_Professionalizing Fire Safety Engineering, Education Report, the Warren Centre, University of Sydney, 2020.pdf [pdf]
… in the UK, and the Shergold/Weir Report1° and various State Cladding inquiries in Australia (for example those in … P, Weir, B (2018) Building Confidence i~ Victorian cladding taskforce, … 17th December 2018 i~ Fire Safety end External Wall Cladding, NSW Government, https://’ww~rfinance nsw gov …
Published on:
JTO00000004_Warren FSE Education Report_2019 (footnote 9 & 24).pdf [pdf]
… in the UK, and the Shergold/Weir Report1° and various State Cladding inquiries in Australia (for example those in … m Shergold, E, Weir, B (2018) Building Confidence Viclorian cladding taskferce, hltps://www.planning vic.gov.au/building-policy/victorian-cladding-taskforce, accessed 171h December 2018 ~ Queensland …
Published on:
CCS0923434692-004_GTI Phase 2 Volume 7_LARGE_3 SEPT_0.pdf [pdf]
… involving fires in high-rise buildings, such as the Lakanal House fire in July 2009, the Shirley Towers fire in … Risk Assessment Group did not consider whether the fires at Lakanal House in July 2009 and Adair Tower in 2015 had … the London Borough of Southwark in the case of the Lakanal House fire and RBKC in the case of the Adair Tower …
Published on:
CCS0923434692-004_GTI Phase 2 Volume 7_BOOKMARKED.pdf [pdf]
… involving fires in high-rise buildings, such as the Lakanal House fire in July 2009, the Shirley Towers fire in … Risk Assessment Group did not consider whether the fires at Lakanal House in July 2009 and Adair Tower in 2015 had … the London Borough of Southwark in the case of the Lakanal House fire and RBKC in the case of the Adair Tower …
Published on:
HAR00003998_Harley specification notes and Sections, C1059-100 Rev C; C1059-301 Rev F; C1059-304 Rev D; C1059-305 Rev D; C1059-325 Rev C; C1059-326 Rev B, annotated.pdf [pdf]
… 9010 MATI (30% GLOSS). U VALUE= 0.77 W/m2K (CENTRE PANE) CLADDING- R1 ALUMINIUM COMPOSITE PANEL, SMOKE SILVER METALLIC DURAGLOSS 5000 SATIN. CLADDING- R2 ALUMINIUM COMPOSITE PANEL, RAL 9010. FIREBREAKS …
Published on: