BBA00011287_Letter from The Loss Preventon Council to BBA re Kooltherm K8 Cavity Boards dated 13 July 1994.pdf [pdf]
… BBA00011287_Letter from The Loss Preventon Council to BBA re Kooltherm K8 Cavity … face was exposed to the heating conditions. Test result: Class I 3. Assessment of test data The test relating to … phenolic foam been tested, it would still be within the class 0 limits defined in appendix A, A12 of Approved …
Published on:
BRE00047463_SH28 - Email from Stephen Howard to Sarah Colwell sent on 02 September 2014 at 13_39 (including chain below).pdf [pdf]
… BRE00047463_SH28 - Email from Stephen Howard to Sarah Colwell sent on 02 September 2014 … panels achieve B-sl-d0 in accordance with EN 13501 and are Class 0, and therefore would meet the requirements for … to be non-combustible (equivalent to limited combustibility/class A2 under the English definitions). For a commercial …
Published on:
EXO00001105_Exova Grenfell Tower Outline Fire Safety Strategy dated 24_10_2013.pdf [pdf]
… EXO00001105_Exova Grenfell Tower Outline Fire Safety Strategy … other than circulation spaces within the apartments - Class 0 (using the UK testing methods) or Class B-s3, d2 (using the European testing methods); and b) …
Published on:
EXO00000430_Exova Grenfell Tower Outline Fire Safety Strategy dated 24_10_2012 Attached to Studio E Fire Strategy sent to building control.pdf [pdf]
… EXO00000430_Exova Grenfell Tower Outline Fire Safety Strategy … other than circulation spaces within the apartments - Class 0 (using the UK testing methods) or Class B-s3, d2 (using the European testing methods); and b) …
Published on:
EXO00001127_An_Exova_Warringtonfire_report_on_the_Grenfell_Tower_refurbishment.pdf [pdf]
… other than circulation spaces within the apartments - Class 0 (using the UK testing methods) or Class B-s3, d2 (using the European testing methods); and … Strategy Warringtonfire 3.1.3 3.1.4 3.1.5 b) elsewhere - Class 1 (using the UK testing methods) or Class C-s3, d2 …
Published on:
CLG00019445_BRE Report on External Fire Spread - Part 1 Background research - April 2016_1.pdf [pdf]
… CLG00019445_BRE Report on External Fire Spread - Part 1 Background research - … the relevant boundary, height and use of the building. The classification of the external surface of a building depends … boundary, regardless of its height, must be European Class B-s3,d2 or National Class O (as defined in AD B) or …
Published on:
ART00001999_Conditional planning permission grant for refurbishment.pdf [pdf]
… of existing Grenfell Tower including new external cladding and fenestration, alterations to plant room, … of existing Grenfell Tower including new external cladding and fenestration, alterations to plant room, … of existing Grenfell Tower including new external cladding and fenestration, alterations to plant room, …
Published on:
CST00000496_Permission for Development (Conditional) Grenfell Tower from RBKC.pdf [pdf]
Published on:
CLG00019445_BRE Report on External Fire Spread - Part 1 Background research - April 2016_2.pdf [pdf]
Published on:
RBK00018801_RBKC Position Statement Supporting Document - Document 07.pdf [pdf]
… RBK00018801_RBKC Position Statement Supporting Document - Document 07.pdf … of lower 4 levels to provide 7 new residential units (use class C3), replacement nursery (use class 01) and boxing club (use class 02) facilities, …
Published on:
CLG00019445_BRE Report on External Fire Spread - Part 1 Background research - April 2016_0.pdf [pdf]
… CLG00019445_BRE Report on External Fire Spread - Part 1 Background research - … the relevant boundary, height and use of the building. The classification of the external surface of a building depends … boundary, regardless of its height, must be European Class B-s3,d2 or National Class O (as defined in AD B) or …
Published on:
CLG00019445_BRE Report on External Fire Spread - Part 1 Background research - April 2016.pdf [pdf]
… CLG00019445_BRE Report on External Fire Spread - Part 1 Background research - … the relevant boundary, height and use of the building. The classification of the external surface of a building depends … boundary, regardless of its height, must be European Class B-s3,d2 or National Class O (as defined in AD B) or …
Published on:
BRE00043792_Exhibit DC_153 - Comments by Corinne Williams on version 3 of External Fire Spread article (Part 1 and Part 2), dated 31 March 2015..pdf [pdf]
… BRE00043792_Exhibit DC_153 - Comments by Corinne Williams on version 3 of External Fire … the relevant boundal¥, height and use of the building. The class~ication of the external surface of a building depends … from the relevant boundary regardless of its height must be Class 0 This means that the external surface should be …
Published on:
MAX00001389_RBKC Conditional Planning Permission.pdf [pdf]
… MAX00001389_RBKC Conditional Planning Permission.pdf MAX00001389_RBKC … of lower 4 levels to provide 7 new residential units (use class C3), replacement nursery (use class D l ) and boxing club (use class D2) facilities, …
Published on:
EXO00000430_Exova Grenfell Tower Outline Fire Safety Strategy dated 24_10_2012 Attached to Studio E Fire Strategy sent to building control_3.pdf [pdf]
… EXO00000430_Exova Grenfell Tower Outline Fire Safety Strategy … other than circulation spaces within the apartments - Class 0 (using the UK testing methods) or Class B-s3, d2 (using the European testing methods); and b) …
Published on: