SEA00009876_Email Chain Between Sounes, Specialised Panels, Rek, Glennon regarding specifications and fire rating for birch plywood_0.pdf [pdf]
… SEA00009876_Email Chain Between Sounes, Specialised Panels, Rek, Glennon regarding … be sufficient way of fixing? -The surface will need pass Class 1 (using the UK testing methods) or Class C-s3, d2 (using the European testing methods) Thank …
Published on:
SEA00009876_Email Chain Between Sounes, Specialised Panels, Rek, Glennon regarding specifications and fire rating for birch plywood.pdf [pdf]
… SEA00009876_Email Chain Between Sounes, Specialised Panels, Rek, Glennon regarding … be sufficient way of fixing? -The surface will need pass Class 1 (using the UK testing methods) or Class C-s3, d2 (using the European testing methods) Thank …
Published on:
Transcript 21 February 2022.pdf [pdf]
Published on:
UKAS0011345_BRE Assessment Report - Ron Withers.pdf [pdf]
… UKAS0011345_BRE Assessment Report - Ron Withers.pdf UKAS0011345_BRE Assessment Report - … error in the schedule is that there are only Resistance classes 1,2 & 3 for BS EN1629:2011, Resistance under Dynamic loading and reference to classes 4, 5 & 6 should therefore be removed And finally, …
Published on:
BBC00000001_Exhibit HOG_1 - Pre-broadcast right of reply correspondence.pdf [pdf]
… BBC00000001_Exhibit HOG_1 - Pre-broadcast right of reply correspondence.pdf … with BS 8414, meeting the requirements of BR 135, and was Class 0 rated. 3. In its marketing, Celotex claimed RS5000 … Tower show RSS000 is highly combustible and does not meet Class 0 standards. 9. On 30~ January 2018, Celotex admitted …
Published on:
BRE00047657_Exova Assessment Putney Plaza 0438_001 dated 23 June 2015.pdf [pdf]
… BRE00047657_Exova Assessment Putney Plaza 0438_001 dated 23 June 2015.pdf … between columns. The Metsec is filled to full depth with Class A 1 Non combustible stone wool • 12mm Calcium Silicate … between columns. The Metsec is filled to full depth with Class A 1 Non combustible stone wool • 12mm Calcium Silicate …
Published on:
BRE00047655_K15 Desktop Study Exova Stone-Alu dated 23 June 2015.pdf [pdf]
… BRE00047655_K15 Desktop Study Exova Stone-Alu dated 23 June 2015.pdf … between columns. The Metsec is filled to full depth with Class A 1 Non combustible stone wool • 12mm Calcium Silicate … between columns. The Metsec is filled to full depth with Class A 1 Non combustible stone wool • 12mm Calcium Silicate …
Published on:
KIN00025945_Phase 2 Module 1 - Written closing submission on behalf of Kingspan Insulation Limited.pdf [pdf]
… KIN00025945_Phase 2 Module 1 - Written closing submission on behalf of Kingspan … by BR 135. 5 Arconic claimed an incorrect reaction to fire classification for its Reynobond PE-cored ACM cladding. The … a B-s2, dO in accordance with EN1351011:2002"- ie a Euroclass B 2 Kingspan Insulation Limited (company number …
Published on:
BSI00000810_BS EN 13501-3_2005+A1_ 2009 - Fire classification of construction products and building elements - Part 3_ Classification using data from fire resistance tests on products and elem.pdf [pdf]
… BSI00000810_BS EN 13501-3_2005+A1_ 2009 - Fire classification of construction products and building elements - Part 3_ Classification using data from fire resistance tests on …
Published on:
CLG00000173_The Building Regulations 2010 (Fire Safety) Approved Document B Volume 2 (Buildings other than dwelling houses) 2006 edition incorporating 2007 & 2010 amendments (online version).pdf [pdf]
… CLG00000173_The Building Regulations 2010 (Fire Safety) Approved Document B Volume 2 … on roof coverings incorporates the new European system of classification set out in BS EN 13501- 5:2005. Main changes … Introduction 82 Section 6: Wall and ceiling linings Classification of linings Variations and special provisions …
Published on:
CCS0923434692-004_GTI Phase 2 Volume 1_LARGE_3 SEPT_0.pdf [pdf]
… CCS0923434692-004_GTI Phase 2 Volume 1_LARGE_3 SEPT_0.pdf CCS0923434692-004_GTI Phase 2 … height, it has prohibited the use of materials that are not classed A2 (s1, d0) or better in the external walls of … safety of external cladding systems (thereby abandoning Class 0). 2.6 The department also failed to pay due regard …
Published on:
SEA00001952_WICTEC Brochure.pdf [pdf]
Published on:
CCS0923434692-004_GTI Phase 2_Report Overview Japanese_HQPC.pdf [pdf]
… CCS0923434692-004_GTI Phase 2_Report Overview Japanese_HQPC.pdf CCS0923434692-004_GTI Phase … 以前の必須要件を、Approved Document B内において、近年開発された大規模テスト に差し替える(よってClass 0を破棄する)べきだという推奨についても、実践もしくは考 慮することをしませんでした。 第2章 … を怠りました。それどころかテスト結果の公表すらされていません。 2.7 その後も、同省は国内Class 0基準は外壁パネルの適正を判断するにあたって不適 …
Published on:
KIN00008807_Exhibit ADH_48 - Sure Fire CPD presentation “Ref – signed off by John Garbutt__0.pdf [pdf]
Published on:
BSR00000064_BSR Team 2 - Phase 2 Module 2 Opening Submissions_0.pdf [pdf]
… BSR00000064_BSR Team 2 - Phase 2 Module 2 Opening Submissions_0.pdf BSR00000064_BSR Team 2 - … led within. ~ey placed misguided reliance on the misnomer N"Class 0’. ~ ~ey did not unde~tm~d the Building Regul~ions.2 … results were published in early 2005 and achieved EuroClass B.~ Reynobond PE cassettes behave very differently …
Published on:
BSR00000064_BSR Team 2 - Phase 2 Module 2 Opening Submissions.pdf [pdf]
… core installed on Grenfell Tower as part of the cladding sys*em. CEP fabricaled the panels into c~settes and … assesses fi~e combustibilfly of a fabricated version of cladding panels incorporated into a cladding system. The riveted system results were published …
Published on:
CLG00000705_Email query from composite panel manufacturer GammaStone to Brian Martin re ADB, fire performance tests required under Building Regs for 18m+ buildings & DCLG response.pdf [pdf]
… Document B is correct. It is not a necessary to classify a cladding system to BS 8414 if the wall construction meets … of composite panels for ventilated facades and buildings cladding. We usually sell our items in UK trough our … is about B5 8414 2 regulation (fire performance of external cladding systems). I would like to know if GammaStone has to …
Published on:
BRE00043866_2021.10.20 Witness Statement of Penny Morgan.pdf [pdf]
… BRE00043866_2021.10.20 Witness Statement of Penny Morgan.pdf BRE00043866_2021.10.20 Witness Statement … ageing o[’those mate~ia]s on buddings. e. The National Class 0 as a classification [br materials which could be used on the …
Published on:
BRE00043861_Exhibit CMH_29 - Attachment to CMH_27 DCLG Journal Article BD2890 (D16V3) 283165 (Approved) containing Brian Martin comments.pdf [pdf]
… BRE00043861_Exhibit CMH_29 - Attachment to CMH_27 DCLG Journal Article BD2890 (D16V3) 283165 … the relevant boundary, height and use of the building. The classification of the external surface of a building depends … the relevant boundary, regardless of its height, must be Class 0. This means that the external surface should be …
Published on: