CEL00001330_NHBC technical guidance note.pdf [pdf]
… CEL00001330_NHBC technical guidance note.pdf CEL00001330_NHBC technical guidance note.pdf … par t ic le board beh ind the insu la t ion ( m i n i m u m Class B as used in several tests and a suggested th ickness … t par t ic le board of m i n i m u m combus t ib i l i t y Class B (when assessed to BS EN 13501:1) Insulat ion ( m a x …
Published on:
CEL00002378_K319-TechGuidanceNote-ApprovedDocB.pdf- Acceptability of common wall constructions containing combustible materials in high rise buildings..pdf [pdf]
… CEL00002378_K319-TechGuidanceNote-ApprovedDocB.pdf- Acceptability of common wall … par t ic le board beh ind the insu la t ion ( m i n i m u m Class B as used in several tests and a suggested th ickness … t par t ic le board of m i n i m u m combus t ib i l i t y Class B (when assessed to BS EN 13501:1) Insulat ion ( m a x …
Published on:
CEL00012235_Celotex - Phase 2 Module 2 Opening Submissions.pdf [pdf]
… CEL00012235_Celotex - Phase 2 Module 2 Opening Submissions.pdf … 2014 and the description of that test in the BRE’s test and classilication reports issued lbllowing the test 0he "BRE … 20 above and additional BS476 tests (which conllrmed the Class 0 and Class 1 classilications of RSS000 and TB4000 …
Published on:
Dr Barbara Lane report - appendix E (Phase 1 - supplemental).pdf [pdf]
… Dr Barbara Lane report - appendix E (Phase 1 - supplemental).pdf Dr Barbara … Architecture Wall Cladding Panel reaction to fire test and classification evidence E-2 E3 Celotex thermal insulation- … Schedule of disclosed National test reaction to fire test/classification E4 reports E-1 0 E3 .3 Variations in the …
Published on:
LFB00054552_Exhibit LD_5 - LFB Policy 879 RecordsManagement Strategy 5_Records retention guidance.pdf [pdf]
Published on:
CEL00000450_Celotex product comparison matrix - final version.pdf [pdf]
… CEL00000450_Celotex product comparison matrix - final version.pdf … Floor Celotex FISOOO Kooltherm Kl03 SRI UF, Eurothane GP Class 0 XOI UF Kooltherm Kl03 SRI UF, Eurothane GP Class 0 XOI UF Concrete Slab Floor Celotex FISOOO Kooltherm …
Published on:
CEL00000449_Celotex Product Comparison Matrix.pdf [pdf]
… CEL00000449_Celotex Product Comparison Matrix.pdf CEL00000449_Celotex … Floor Celotex FISOOO Kooltherm K3 SRI UF, Eurothane GP Class 0 XOIUF Concrete Slab Floor Celotex FISOOO Kooltherm K3 SRI UF, Eurothane GP Class 0 XOIUF Beam & Block Floor Celotex FISOOO Kooltherm K3 …
Published on:
KIN00008852_Exhibit AJB_2_ Kooltherm K15 Rainscreen Board Fire Ratings Technical Note for England and Wales (Internal use only). First Issue dated April 2018.pdf [pdf]
… KIN00008852_Exhibit AJB_2_ Kooltherm K15 Rainscreen Board Fire Ratings Technical Note … Rating Summary Kingspan Kooltherm K15 Rainscreen Board is Class D, as defined in Approved Documents Bin England and … in Scotland. Kingspan Kooltherm K15 Rainscreen Board is classified as Euroclass C-s1, dO in accordance with BS EN …
Published on:
KIN00008734_Exhibit MJPE_2 - Kooltherm K15 Rainscreen Board Fire Ratings Technical Note for England and Wales (Internal use only). First Issue dated April 2018.pdf [pdf]
… KIN00008734_Exhibit MJPE_2 - Kooltherm K15 Rainscreen Board Fire Ratings Technical Note … Rating Summary Kingspan Kooltherm K15 Rainscreen Board is Class D, as defined in Approved Documents Bin England and … in Scotland. Kingspan Kooltherm K15 Rainscreen Board is classified as Euroclass C-s1, dO in accordance with BS EN …
Published on:
KIN00008778_Exhibit ADH_23 - Kooltherm K15 Rainscreen Board Fire Ratings Technical Note for England and Wales (Internal use only). First Issue dated April 2018_0.pdf [pdf]
… KIN00008778_Exhibit ADH_23 - Kooltherm K15 Rainscreen Board Fire Ratings Technical Note … Rating Summary Kingspan Kooltherm K15 Rainscreen Board is Class 0, as defined in Approved Documents Bin England and … in Scotland. Kingspan Kooltherm K15 Rainscreen Board is classified as Euroclass C-s1, dO in accordance with BS EN …
Published on:
NHB00001283_NHBC Technical Guidance Notes (NHBC Standards Requirements) re external fire spread_ Brickwork Facade, Cavity Barriers, Timber Panelling and Aluminium Composite Panels - Seminar _F.pdf [pdf]
… NHB00001283_NHBC Technical Guidance Notes (NHBC Standards Requirements) re external fire spread_ … A 140mm Kooltherm K15 Mineral Composite Grooved Tiles (Euroclass B) Pass PN 302995 Cement Particle Board (Type A2 … provision around openings and compartment lines • Minimum Class B lining board • Comparison of insulation type and …
Published on:
CTAR00000042_London Building Acts (Amendment) Act 1939 Section 20. Code of Practice. Greater London Council..pdf [pdf]
… CTAR00000042_London Building Acts (Amendment) Act 1939 Section 20. Code of … -adKifift the danger arising from fire within certain classes of buildings by reason of height, cubical extent … (3) and item 1.02); b no building of the warehouse class and no building or part of a building used for …
Published on:
BRE00047667_2021.12.14 Witness statement of Raymond Connolly.pdf [pdf]
… BRE00047667_2021.12.14 Witness statement of Raymond Connolly.pdf BRE00047667_2021.12.14 Witness … with over 30 years relevant experience. I hold a first class honours Bachelor of Engineering (BE) degree from … were also contributory features. It was understood that Class 0 materials are combustible. (c) My understanding was …
Published on:
PAN00000020_2019.08.06 Witness statement of Christopher Malcolm Ibbotson.pdf [pdf]
… PAN00000020_2019.08.06 Witness statement of Christopher Malcolm Ibbotson.pdf PAN00000020_2019.08.06 … of designing the panel composition. These may include: - a) Class 1 Surface Spread of Flame b) Class 'O' to Building Regulations c) Non-Combustible Core." …
Published on:
BRE00043853_Exhibit CMH_21 - Research Report_ Investigation of Real Fires - External fire spread in multi-storey buildings (E7V1).pdf [pdf]
… BRE00043853_Exhibit CMH_21 - Research Report_ Investigation of Real Fires - External fire spread in … resistance to fire for a specific period of time), "Class 3" (National fire classification) and "Class B s2,d0" (European fire …
Published on:
CLG00014745_BRE - DCLG Report_ BD 2890 Investigation of real fires - External fire spread in multi-storey buildings dated 9 January 2014.pdf [pdf]
… CLG00014745_BRE - DCLG Report_ BD 2890 Investigation of real fires - External fire … resistance to fire for a specific period of time), "Class 3" (National fire classification) and "Class B s2,d0" (European fire …
Published on:
BRE00043751_Exhibit DC_115 - Investigation of real fires - External fire spread in multistorey buildings report dated 9 January 2014..pdf [pdf]
… BRE00043751_Exhibit DC_115 - Investigation of real fires - External fire spread in multistorey … resistance to fire for a specific period of time), "Class 3" (National fire classification) and "Class B s2,d0" (European fire …
Published on:
BRE00035381_North Ayrshire Council's file in relation to the fire at Garnock Court in Irvine, Scotland (part 2 of 2) - Includes a draft, marked up version of the BRE's report into the fire_1.pdf [pdf]
… BRE00035381_North Ayrshire Council's file in relation to the fire at … cladding for Garnock Court and the four sister blocks was Class 0 at the time of the fire. 2. It is also highly likely that the GRP supplied would never have achieved Class 0. 3. The poor fire performance would not have …
Published on:
INQ00015102_SCHEDULE OF QUESTIONS REFERRED TO IN THE WITNESS STATEMENT OF DR RAYMOND CONNOLLY.pdf [pdf]
… and any employment within the construction, fire safety and cladding industries. 2. In relation to your employment by … any dealings you had with any manufacturers of rainscreen cladding or insulation products in relation to fire safety … "The 1988 scheme involved the use of Class 0 GRP rainscreen cladding on aluminium support rails ... Cavity barriers were …
Published on:
BSR00000096_BSR Team 1A - Phase 2 Module 6 Written Opening (Government, FRA, Testing and Certification) Submissions [Bindmans, Hickman & Rose, Hodge Jones & Allen].pdf [pdf]
… BSR00000096_BSR Team 1A - Phase 2 Module 6 Written Opening (Government, FRA, Testing and … the external wall and cladding, allowing the latter to be Class 0 albeit the definition of Class 0 was then different. The 1965 Building Regulations …
Published on: